Electrical & Power Systems

Industrial electrical and power systems engineering spanning substations, distribution, large motors and drives, protection, studies, electrical buildings, commissioning and operating facility support across oil and gas, refining, oil sands, cogeneration and gas processing environments.

144 and 145 kV class systems

UEI
ZR3PJZEA7A21
CAGE
174X8
Independence
Findings challenged before release
Deployment
Remote response within 24 hours

What This Discipline Covers

Scope of the technical capability.

Industrial electrical and power systems engineering spanning substations, distribution, large motors and drives, protection, studies, electrical buildings, commissioning and operating facility support across oil and gas, refining, oil sands, cogeneration and gas processing environments.

  • Power distribution
  • Substations
  • Transformers
  • Switchgear
  • MCCs
  • Generators
  • Motors
  • VFDs
  • UPS and DC systems
  • Load flow
  • Short circuit
  • Motor starting
  • Harmonics
  • Arc flash
  • Relay coordination
  • Electrical calculations
  • Area classification
  • Heat tracing
  • Commissioning and startup

Problems The Technical Lead Solves

The questions this discipline is engaged to answer.

  1. 01

    Electrical failures

  2. 02

    Protection and relay issues

  3. 03

    Power system studies

  4. 04

    Motor and drive problems

  5. 05

    Substation and distribution review

  6. 06

    Commissioning

  7. 07

    Electrical design review

  8. 08

    Power quality, arc flash and short circuit

Equipment And Systems

Assets this Technical Lead has worked on directly.

  • 145 kV substations
  • Power transformers
  • 25, 13.8 and 4.16 kV switchgear
  • MCCs
  • Large synchronous motors
  • Compressors
  • Electrical buildings
  • Generators, UPS and DC systems

Industries And Environments

Operating environments where this experience was built.

  • Oil sands and SAGD
  • Refining and upgrading
  • Gas processing
  • Pipelines
  • Cogeneration
  • Oil and gas

Diagnostic And Investigation Methods

How the technical work is actually performed.

  • Sequence of events and relay target reconstruction
  • Waveform and power quality analysis
  • Protection coordination and settings verification
  • Insulation, winding, and dielectric condition assessment
  • Control logic, alarm, and interlock review
  • Arc flash and incident energy evaluation

Tools Capability

The platforms, instruments and measurement methods used on assignments.

These platforms, instruments and methods are used to produce evidence that holds up under audit, underwriting review and cross examination.

Power System Analysis

  • ETAP

    Load flow, short circuit, coordination, arc flash to IEEE 1584, motor starting, grounding and harmonic study.

  • SKM PowerTools

    Industrial electrical studies, coordination and incident energy analysis.

  • EasyPower

    Independent verification of coordination, short circuit and arc flash results on a second recognised platform.

Event and Disturbance Evidence

  • Relay event records, SEL AcSELerator and COMTRADE analysis

    Reconstruction of trip sequence, fault type, fault current and protection response to the millisecond.

  • Power quality analyzers, including Fluke and Dranetz instruments

    Voltage sag, transient and harmonic evidence associated with equipment damage claims.

  • Doble and Megger test sets

    Insulation resistance, power factor, turns ratio and winding condition testing on transformers, motors and cables.

  • Dissolved gas analysis and infrared thermography

    Transformer condition assessment and connection or termination heating evidence.

Switchgear, Breaker and SF6 Condition Evidence

  • Circuit breaker timing and travel analysis

    Contact travel, operating and clearing time measured against the manufacturer curve to establish whether the breaker cleared the fault as designed.

  • Contact resistance and dynamic contact resistance testing

    Micro-ohm measurement of bolted joints, bus connections and breaker contacts where heating is suspected as the initiating condition.

  • Protective relay secondary injection testing

    Omicron and Doble class injection to verify as found settings, pickup, timing and logic against the coordination study.

  • Offline and handheld partial discharge survey, including ultrasonic and TEV instruments

    Detection of insulation degradation, tracking and corona in energised medium voltage switchgear before an arc path forms.

  • SF6 gas density, moisture and purity analysis

    Gas condition and leak history in gas insulated switchgear, including density lockout records that may predate the event.

  • SF6 decomposition by-product analysis for SO2, SOF2 and HF

    Chemical signature of internal arcing used to confirm that an arc occurred inside a sealed compartment and to estimate its severity.

  • SF6 recovery, handling and emissions accounting to IEC 62271 and IEEE C37.122 practice

    Documented gas recovery after an internal arc, with the released mass quantified for environmental reporting.

Underground Cable Systems and Accessories

  • Time domain reflectometry, impulse and bridge fault location

    Location of a fault along an underground transmission or distribution route before excavation, including discrimination between cable length and accessory.

  • Sheath fault location and oversheath DC testing

    Verification that the external protective and water barrier system is intact after installation, repair or backfilling.

  • Mobile series resonant AC withstand test system

    After installation acceptance testing of extruded cable systems to IEC 60840 practice at 115 kV class, where very low frequency testing is not the appropriate instrument.

  • Distributed and local partial discharge measurement on cable systems

    Detection of localised dielectric activity at joints and terminations under AC voltage, where installation defects in field assembled accessories typically appear.

  • Soil and backfill thermal resistivity probe and laboratory testing

    Field and laboratory measurement to IEEE 442 practice to establish whether the buried environment supports the ampacity and rating assumptions under IEC 60287.

  • Sheath bonding, link box and sheath voltage limiter verification

    Continuity, circulating current and bonding configuration checks where sheath heating or bonding error is a candidate cause or a post repair risk.

  • Distributed temperature sensing on cable routes

    Thermal profile of the circuit along its length, used to identify hot sections, dried backfill and repaired segments running above the adjacent cable.

  • Cable locator, as built and GIS route reconciliation with ground penetrating radar

    Confirmation that the installed route matches the record relied on by excavation and locate processes, which is central to third party damage causation.

  • Jointing dimensional control, calibrated preparation tooling and hold point records

    Demonstration of field workmanship against AEIC CG4 and manufacturer qualified procedures after a joint is closed and backfilled.

Root Cause and Analytical Method

  • Fault tree analysis and event and causal factor charting

    Ordering of protection, control and human actions into a single defensible sequence.

  • Apollo Root Cause Analysis and TapRooT

    Cause determination for switchgear faults, transformer losses and unplanned outages under claim.

Monitoring, Sensors and Predictive Analytics

  • Online partial discharge and thermal monitoring

    Continuous evidence of insulation degradation in switchgear, cables and transformers.

  • AI camera and thermal monitoring

    Automated watch on substations and switchrooms where access is restricted or hazardous.

Remote and Visual Access

  • Drone thermography of lines, structures and yards

    Overhead and elevated electrical asset survey without an outage.

  • Borescope inspection of enclosures and terminations

    Internal arc damage and contamination evidence before equipment is cleaned.

BlackOut Power / TerraTolga Proprietary Capability

Codes And Standards

Frameworks applied to the analysis.

  • NFPA 70 and NFPA 70E
  • IEEE 242, 399, 1584 and C57 series
  • NETA acceptance and maintenance testing specifications
  • IEC 61508 and IEC 61511 for safety instrumented systems
  • IEC 60909 short circuit calculation
  • NETA acceptance testing
  • IEEE C57 transformer testing

Credentials And Qualification

The professional basis for this discipline.

  1. 01

    Electrical engineering background with utility or industrial power system experience

  2. 02

    Protection, controls, and automation platform experience across major vendors

  3. 03

    Testing and commissioning experience on medium and high voltage apparatus

  4. 04

    Mission critical facility operations exposure

Scale And Breadth

Reported scale of professional exposure.

  • 01

    144 and 145 kV class systems

  • 02

    90, 120 and 150 MVA three winding transformers

  • 03

    17,500 HP synchronous CO2 compressor power and control system

  • 04

    Voltage range from 144, 72, 25, 13.8, 4.16 and 0.6 kV

Representative Professional Experience

Assignment types this discipline supports.

  1. 01

    Origin determination for a medium voltage switchgear arcing event including protection performance review

  2. 02

    Reconstruction of a mission critical outage from electrical monitoring, UPS, and generator records

  3. 03

    Assessment of transformer failure cause and resulting damage scope for a claim

  4. 04

    Control system logic review establishing why an automated protective action did not occur

Assignment descriptions are generalized to protect client confidentiality. Specific references can be discussed during scoping where permissions allow.

Multidisciplinary Interfaces

Disciplines this work commonly coordinates with.

  • Controls
  • Mechanical & RCA
  • Machinery
  • Process
  • Reliability

Discuss a electrical & power assignment.

Initial conversations are confidential and without obligation. We will confirm independence before scope is discussed.

Discuss a matter in confidence